Ken heater product application range
Designed and produced by our companyHeaterProducts can be widely used in wind power generation, petrochemical industry, iron and steel metallurgy, mechanical lubrication, biomedicine, nuclear power engineering, road machinery, new energy vehicles and other industries. Including the design, system solutions and production of conventional electric heaters; customization of non-standard electric heaters such as wind power gearboxes and ducted heaters, including design and manufacturing.
Surface load parameter table
Series for conventional oil:
1、SRY2/SRY4 immersion oil heater.
SRY2 and SRY3 tubular electric heaters are used for heating oil in open or closed oil tanks; SRY4 tubular electric heater components are used for heating flowing or circulating oil. The fixed type heater has a higher surface load and is only suitable for heating. Use in oil with good effect.
model | Voltage | power | Outline and installation dimensions (mm) | ||
A | B Invasive oil long | Surface load | |||
SRY2-220/1 | 220V/380V | 1 | 307 | 230 | 2.9 |
SRY2-220/2 | 220V/380V | 2 | 507 | 430 | 3.1 |
SRY2-220/3 | 220V/380V | 3 | 707 | 630 | 3.2 |
SRY2-220/4 | 220V/380V | 4 | 922 | 845 | 3.1 |
SRY4-220/5 | 220V/380V | 5 | 697 | 620 | 5.3 |
SRY4-220/6 | 220V/380V | 6 | 807 | 730 | 5.5 |
SRY4-220/8 | 220V/380V | 8 | 1007 | 930 | 5.7 |
2、SRY2-1/SRY2-2Type threaded oil heater
Used for heating oil in the oil tank of high-precision thin oil station.
model | Voltage | power | L | L1 | φ | G |
SRY2-1 | 220V | 1KW | 1000 | 900 | 52 | 2" |
SRY2-2 | 220V | 1.5KW | 1000 | 900 | 76 | 2.5" |
3、SRY2-3(HRY14)Type intrusive electric heater
Used to heat oil in a closed tank.
power | A | B | Surface load |
1KW | 400 | 300 | 1.5 |
2KW | 690 | 590 | 1.5 |
3KW | 990 | 890 | 1.5 |
4KW | 1280 | 1180 | 1.5 |
5KW | 990 | 890 | 2.5 |
6KW | 1160 | 1060 | 2.5 |
8KW | 1520 | 1420 | 2.5 |
4、SRY5(HRY10、HRY11、HRY12、HRY13)Overhead square oil heater
It is used for heating the medium of hydraulic lubrication, and it can also be used for heating non-corrosive gas.
SRY5-II (HRY12) overhead square type technical parameters and main dimensions:
parameter | Heater | Surface load of electric heating tube(w/c㎡) | power | Voltage(v) | Heating zone size B(mm) | φ | φ | φ | φ | Remark |
SRY5 1-A/B | 12 | 0.7 | 1 | 380/220 | 630 | 150 | 120 | 90 | 4-φ11 | |
SRY5 2-A/B | 12 | 0.7 | 2 | 380/220 | 1260 | 150 | 120 | 90 | 4-φ11 | |
SRY5 3-A/B | 12 | 0.7 | 3 | 380/220 | 1900 | 150 | 120 | 90 | 4-φ11 | |
SRY5 4-A/B | 12 | 0.7 | 4 | 380/220 | 2520 | 150 | 120 | 90 | 4-φ11 | |
SRY5 5-A/B | 12 | 0.7 | 5 | 380/220 | 3150 | 150 | 120 | 90 | 4-φ11 | |
SRY5 6-A/B | 12 | 0.7 | 6 | 380/220 | 3780 | 150 | 120 | 90 | 4-φ11 |
SRY5-II(HRY13)Top-mounted square type technical parameters and main dimensions:
parameter | Heater | Surface load of electric heating tube(w/c㎡) | power | Voltage(v) | Heating zone size B(mm) | φ | φ | φ | φ | Remark |
SRY5 1-A/B | 12 | 1.2 | 1 | 380/220 | 370 | 150 | 120 | 90 | 4-φ11 | |
SRY5 2-A/B | 12 | 1.2 | 2 | 380/220 | 740 | 150 | 120 | 90 | 4-φ11 | |
SRY5 3-A/B | 12 | 1.2 | 3 | 380/220 | 1100 | 150 | 120 | 90 | 4-φ11 | |
SRY5 4-A/B | 12 | 1.2 | 4 | 380/220 | 1470 | 150 | 120 | 90 | 4-φ11 | |
SRY5 5-A/B | 12 | 1.2 | 5 | 380/220 | 1840 | 150 | 120 | 90 | 4-φ11 | |
SRY5 6-A/B | 12 | 1.2 | 6 | 380/220 | 2210 | 150 | 120 | 90 | 4-φ11 |
SRY5-III(HRY10)Top-mounted square type technical parameters and main dimensions:
Parameters | Heater | Surface load of electric heating tube(w/c㎡) | power | Voltage(v) | Heating zone sizeB(mm) | φ | φ | φ | φ | Remark |
SRY5 1-A/B | 16 | 0.7 | 1 | 380/220 | 500 | 200 | 170 | 120 | 16-9 | |
SRY5 2-A/B | 16 | 0.7 | 2 | 380/220 | 950 | 200 | 170 | 120 | 16-9 | |
SRY5 3-A/B | 16 | 0.7 | 3 | 380/220 | 1400 | 200 | 170 | 120 | 16-9 | |
SRY5 4-A/B | 16 | 0.7 | 4 | 380/220 | 1900 | 200 | 170 | 120 | 16-9 | |
SRY5 5-A/B | 16 | 0.7 | 5 | 380/220 | 2380 | 200 | 170 | 120 | 16-9 | |
SRY5 6-A/B | 16 | 0.7 | 6 | 380/220 | 2850 | 200 | 170 | 120 | 16-9 |
SRY5-III(HRY11)Top-mounted square type technical parameters and main dimensions:
Parameters | Heaterφ(mm) | Surface load of electric heating tube(w/c㎡) | power(kw) | Voltage(v) | Heating zone size B(mm) | φ | φ | φ | φ | Remark |
SRY5 1-A/B | 16 | 1.2 | 1 | 380/220 | 280 | 200 | 170 | 120 | 16-9 | |
SRY5 2-A/B | 16 | 1.2 | 2 | 380/220 | 560 | 200 | 170 | 120 | 16-9 | |
SRY5 3-A/B | 16 | 1.2 | 3 | 380/220 | 840 | 200 | 170 | 120 | 16-9 | |
SRY5 4-A/B | 16 | 1.2 | 4 | 380/220 | 1100 | 200 | 170 | 120 | 16-9 | |
SRY5 5-A/B | 16 | 1.2 | 5 | 380/220 | 1380 | 200 | 170 | 120 | 16-9 | |
SRY5 6-A/B | 16 | 1.2 | 6 | 380/220 | 1660 | 200 | 170 | 120 | 16-9 |
5、SRY6-1、2、3(HRY1、2、3)Type sheathed heater
It is used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and can also be used for heating non-corrosive gases and liquids.
6、SRY6-4、5、6、7(HRY4、5、6、7)Type sheathed heater
Used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and also for heating non-corrosive gases and liquids
7、SRY6-8Type sheathed heater
Used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and also for heating non-corrosive gases and liquids
Voltage | power | Surface load of electric heating tubew/c㎡ | Sheath surface load w/c㎡ | L1(mm) |
220V/380V | 1KW | 0.9 | 0.7 | 350 |
220V/380V | 2KW | 0.9 | 0.7 | 700 |
220V/380V | 3KW | 0.9 | 0.7 | 1050 |
220V/380V | 4KW | 0.9 | 0.7 | 1400 |
220V/380V | 5KW | 0.9 | 0.7 | 1750 |
8. SRY6-9 sheathed heater
It is used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and can also be used for heating non-corrosive gases and liquids.
Voltage | power | Surface load of electric heating tubew/c㎡ | Sheath surface load w/c㎡ | L1(mm) |
220V/380V | 1KW | 0.6 | 0.7 | 580 |
220V/380V | 2KW | 0.6 | 0.7 | 860 |
220V/380V | 3KW | 0.6 | 0.7 | 1150 |
220V/380V | 4KW | 0.6 | 0.7 | 1430 |
220V/380V | 5KW | 0.6 | 0.7 | 1720 |
9、SRY7Type straight rod heater
Suitable for supporting national key engineering projects, 300 cubic meters and 200 cubic meters of thin oil stations.
10、SRY8(HRY8、9)Finned heater
Used for heating of hydraulic lubrication medium, non-corrosive gas and liquid.
11、SRY9Type sheathed heater
This model uses multiple φ38 stainless steel electric heaters as a group, and a temperature control regulator is installed on the heater.
12、SRY9-1Heat conduction oil heater
This model uses multiple electric heating elements as a set, and a protective sleeve is added to the heating tube. The electric heating element is placed in the sleeve and is designed with temperature control and temperature adjustment. Refer to SRY6-2 for specific dimensions
13、SRYY6Type sheathed heater
It is used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and can also be used for heating non-corrosive gases and liquids.
Conventional electric heater series
1、SRQAir heater
It is used for heating hydraulic and lubricating oil in hydraulic and lubricating devices, and can also be used for heating non-corrosive gases and liquids.
2、SRXY, SRJ nitric acid solution, alkali solution heater
The SRXY tubular electric heating element is used to heat the nitrate solution. The SRJ tubular electric heating element heats the alkali solution.
3. SRS type water heater
SRS type is suitable for heating water in open and closed water tanks and circulating systems.
4. SRM mold heater
SRS type is suitable for heating metal molds.
5. SRW far infrared heater
SRW type is suitable for the blowing duct of the air heating system, used for blowing hot air, and can also be used as the heating element of various ovens, paint drying, and electric furnaces.
6. SRK3 channel heater
Used to supply heated flowing air in the ventilation duct.
7, LGRQ1, LGRQ2, LGRQ3, LGRQ4 type biphenyl heater
The biphenyl boiler electric heater is a domestically produced product based on a foreign prototype. The modified product is manufactured according to the original machine standard, and the connection is accurate when used, which is convenient and universal.
8. GHK series hot air heater
The GHK series hot air heater is a product developed and designed specifically for heating large equipment and pipelines, removing humidity and garbage inside the pipeline, absorbing the design experience of foreign products.
Wind power heater
1. SRY6F electric heater for wind power gearbox
A heater designed for wind power gearboxes, suitable for heating the lubricating oil in the wind power gearboxes, and can also be used to heat the lubricating oil on the outdoor oil tank.
2. Electric heater for GHY6 wind power gearbox
A heater specially used for heating the lubricating oil in the gearbox of the wind power gearbox.
Pipeline electric heater (online heater series)
Suction heater (built-in heater)
Model: GHY-N, GHY-N1